Header tank inspection in Crediton

Looking for professional header tank inspection help in Crediton? Hembury Contracting provides reliable plumbing services across Crediton and surrounding areas.

Price Guide

£60

Typical Duration

30-60 mins

Location

Crediton

Loft header tanks inspected thoroughly to spot problems before they cause damage. I check tank condition, ballcock operation, overflow, insulation, and support - then give you honest advice on what (if anything) needs doing.

### Your Loft Tank - Out Of Sight, Out Of Mind

Most people never go in their loft, so the **header tank sits there for decades** unnoticed. Until it cracks and dumps water through the ceiling, or the ballcock fails and the overflow's been dripping outside for months wasting water.

> 💡 **Pro tip:** Get your loft tank inspected before buying or selling a house. Buyers' surveys often flag tank issues, and it's better to know beforehand than have it scupper a sale or become a negotiating point.

---

### Quick Look vs Proper Inspection

There's glancing at a tank, and actually checking it properly:

| ✅ Proper Inspection | ❌ Quick Glance | |---------------------|-----------------| | Tank checked for cracks, corrosion, limescale | "Looks OK from here" | | Ballcock operation tested | Assume it's working | | Water level checked against overflow | Not measured | | Support checked (across joists?) | Didn't look | | Insulation inspected | Didn't notice | | Overflow traced to outside | Assume it goes somewhere |

---

### What You Get

**🔧 The Inspection**

| What I Check | What I'm Looking For | |--------------|---------------------| | **Tank body** | Cracks, splits, corrosion, limescale buildup | | **Ballcock** | Shuts off properly? Worn washer? Arm bent? | | **Water level** | Correct height below overflow? | | **Overflow** | Directed outside? Working properly? | | **Support** | Tank sitting across joists? Proper platform? | | **Insulation** | Jacket fitted? Lid in place? | | **Connections** | Pipes secure? Compression joints tight? |

**📦 You're Left With** - Full understanding of tank condition - Photos of any issues - Written report if needed - Honest advice on repairs or replacement - Quote for any work needed

---

### Pricing

| Service | Time | You'll Pay | |---------|------|------------| | Header tank inspection | 30-60 mins | **£60** (minimum) | | Inspection + minor adjustment | Within 1 hr | **£60** (included) |

*£60 minimum callout. If inspection reveals work needed, I'll quote separately.*

---

### Perfect For Your Project If...

✅ **Pre-purchase survey** - check tank before buying house

✅ **Pre-sale check** - fix problems before listing property

✅ **Periodic maintenance** - spot problems before they cause damage

✅ **After plumbing issues** - check if tank's contributing to problems

Why Choose Us for Header tank inspection in Crediton?

Tank condition assessed properly

Potential problems identified early

Ballcock and overflow checked

Honest advice on repairs or replacement

What to Expect

### Step 1: Access Loft I climb into your loft and locate the header tank (and expansion tank if you've got one). Check there's safe access and I can get to the tank properly. ### Step 2: Visual Inspection Look at the tank body for cracks, splits (plastic tanks), rust or corrosion (metal tanks), limescale buildup. Check it's sitting properly on joists or platform. ### Step 3: Ballcock Check Watch the ballcock in action - does it shut off cleanly when water reaches the right level? Is the arm bent? Washer worn? Valve corroded? ### Step 4: Water Level Measure water level relative to overflow outlet. Should be about 50-75mm below. Too high and it'll overflow with pressure fluctuations. ### Step 5: Overflow Check Trace the overflow pipe - does it actually go outside? Is it dripping? Some old installations have overflows that just dump into the loft (very bad). ### Step 6: Insulation & Lid Check if tank jacket's fitted and in good condition. Check lid's in place (keeps dirt, insects, and debris out). ### Step 7: Report Back Come down, explain what I found, show you photos, advise what (if anything) needs doing. Written report if you need one for mortgage/survey purposes.

Our Crediton Service Coverage

We cover Crediton and a 30-mile radius from Exeter, meaning you get local service with the backing of an established business. Whether you're in the centre of Crediton or in the surrounding villages, we're here to help.

Good to Know

> 🏠 **Two tanks in your loft?** Older houses often have a cold water storage tank (big one) and a smaller expansion tank for the heating system. Different purposes - make sure you know which is which. **Age matters** - plastic tanks last 20-30 years typically. Galvanized steel tanks last longer but corrode from inside. If your tank's 20+ years old and you're buying the house, factor in replacement cost. **Insulation** - tank jackets aren't just about heat loss, they stop the tank freezing in cold winters. If yours hasn't got one, you need one. £20 well spent. **Support critical** - full tank weighs about 230kg (50-gallon tank). Must sit across joists or on proper platform. If it's between joists resting on plasterboard, it'll eventually fall through your ceiling. **Overflow outside** - building regs say overflows must discharge where they're visible (so you know there's a problem). Some old installations just dump into the loft - rot central. Needs fixing.

Frequently Asked Questions about Header tank inspection in Crediton

What do you check during a header tank inspection?

Tank condition (cracks, corrosion, leaks), ballcock operation (shuts off properly?), water level (correct height?), overflow (works and directed outside?), insulation (tank jacket fitted?), lid (keeps dirt out?), and support (tank sitting on joists properly?). Full check to spot problems before they cause damage.

How often should I get my loft tank inspected?

Every few years is sensible, especially in older houses. Also get it checked if you've had plumbing problems, notice reduced water pressure, hear constant running water, or planning to sell (buyers' surveys often flag tank issues).

Can you tell if my tank needs replacing during inspection?

Yes - I'll check for cracks, corrosion (metal tanks), limescale buildup, sagging support, and age. If it's got years left, I'll tell you. If it's about to fail, I'll tell you that too. Honest assessment, no BS.

What happens if you find problems?

I'll explain what's wrong, what needs doing (if anything), and give you options. Might be simple fix like adjusting the ballcock, or might need new tank. You decide what to do and when - I just give you the information.

Do I need to be there during the inspection?

Not necessarily - as long as I can access your loft, I can do the inspection. I'll take photos and give you a full report afterwards. But if you want to see what I'm talking about, you're welcome to climb up and have a look.

Also Covering Nearby:

Get a Free Quote in Crediton

Call us today for a free, no-obligation quote for your header tank inspection job in Crediton.

01392 964094Request Online Quote

Pricing for Crediton

Minimum charge£60
Includes callout + first hour
Additional time£50/hr
This Job£60

* Same rates for all locations in our service area

Got multiple jobs?

Make the most of your first hour - I can often tackle several small tasks in one visit. List everything you need done when you call!

Trusted in Crediton

Fully Insured
Local to Crediton
Quick Response
No Hidden Costs

Ready to Book in Crediton?

Get a free quote for your header tank inspection job in Crediton today.